Nuclear Street.

← News archive

NRC Considers Enforcement Action at Oconee Nuclear Plant

Source:

Archived news summary. This item reflects its original publication date. Follow the source link below for the publisher’s full article.

The Nuclear Regulatory Commission is considering escalated enforcement for an apparent violation at the Oconee nuclear plant involving a weld inspection procedure the agency said was inadequate to prevent a leak in a safety system.

In November, unit 1 at the South Carolina plant shut down after a small leak in a high pressure injection system. It was repaired and caused no immediate danger to the reactor or the public. Nonetheless, the NRC is considering a greater-than-green regulatory finding because plant operator Duke Energy did not discover a cracked weld earlier.

"In 2004, a procedure was developed for augmented in-service inspection program ultrasonic examinations, which effectively removed reasonable assurance that HPI nozzle component weld cracking would be identified and corrected," the NRC wrote in a letter to the utility.

After the leak, the NRC reported, a review of 2011 radiographic film revealed indications of a crack extending about 50 percent through the weld. The agency has scheduled a regulatory conference with Duke July 31 to discuss the apparent violation before making an enforcement decision.